Analysis Of Load Balance In 20 Kv Distribution Systems On Power Losses

Authors

  • Bambang Winardi Department of Electrical Engineering, Diponegoro University, Semarang, Indonesia Author
  • Karnoto Department of Electrical Engineering, Diponegoro University, Semarang, Indonesia Author
  • Ajub Ajulian ZM Department of Electrical Engineering, Diponegoro University, Semarang, Indonesia Author

DOI:

https://doi.org/10.62504/jimr892

Keywords:

load balance, voltage drop, power loss

Abstract

Load balancing is one of the things that must be considered by reducing the value of voltage drops or power losses that occur in distribution channels. It is necessary to know the characteristics of the load in an area or area with a balanced supply so that each phase is burdened evenly. Calculating the voltage drop on the distribution network conductors, the voltage drop on the KBN09 Slawi feeder was calculated. What will be calculated here is from the line to the transformer furthest from the GI, namely from the three-phase 20 kV main line, single-phase branching. The results of power calculations from GI Kebasen Tegal show differences between R, S and T phases with three 20 kV phases in pre-balance and post-balance conditions. As written, the value for R wire is 82661.52 W, for S 52613 W, while for the T phase the value is 60127.06 W. Meanwhile, the calculation of power losses from GI Kebasen Tegal shows differences between the R, S and T phases with 1 phase voltage in the conditions before balance and after balanced. On the 3-phase line for the R wire, the power loss decreases from 34,198 W to 17,0425 W, for S it increases from 11,540 W to 19,077 W, while for the T phase the value remains 15,274 W.

Downloads

Download data is not yet available.

References

A. Mohamed Imran and M. Kowsalya, “A new power system reconfiguration scheme for power loss minimization and voltage profile enhancement using Fireworks Algorithm,” Int. J. Electr. Power Energy Syst., vol. 62, pp. 312–322, Nov. 2014

Akbar, A.A. Calculation of Power Shuts On Medium Voltage Distribution System of Air and

Cable Channels. (2007).

A. Pană, A. Băloi, and F. Molnar-Matei, “New method for calculating the susceptances of a balancing capacitive compensator for a three-phase four-wire distribution network,” Int. J. Electr. Power Energy Syst., vol. 115, p. 105414, Feb. 2020

E. F. Ferreira and J. D. Barros, “Faults Monitoring System in the Electric Power Grid of Medium Voltage,” Procedia Comput. Sci., vol. 130, pp. 696–703, 2018,

Elisa Lubis,. Study of Loss Loss Energy Loss on Melon 20 KV Repeaters". (2008)

Erhaneli E 2016 “Evaluasi Keandalan Sistem Distribusi Tenaga Listrik Berdasarkan Indeks Keandalan Saidi Dan Saifi Pada PT . PLN (Persero) Rayon Bagan Batu Tahun 2015” Jurnal Teknik Elektro-ITP 5 .

Fatoni A 2017 “Analisa Keandalan Sistem Distribusi 20 kV PT. PLN Rayon Lumajang dengan Metode FMEA (Failure Modes and Effects Analysis )” Jurnal Teknik ITS 5

Fauziah F, Penangsang O and Soeprijanto A 2012 “Studi Perbaikan Keandalan Jaringan Distribusi Primer Dengan Pemasangan Gardu Induk Sisipan Di Kabupaten Enrekang Sulawesi Selatan” Jurnal Teknik ITS 1 (1) pp. B119-B124.

Muhammad Taufik Akbar, “Analisa Perhitungan Susut Teknis dengan MetodePendekatan Kurva Beban pada Jaringan Distribusi PT PLN (Persero) Rayon Gandapura,” Tugas Akhir pada Jurusan Teknik Elektro Universitas Malikussaleh, Lhokseumawe, 2019.

Muhdar, Isla. Juniarti and Suherman Yunus. "Drop Voltage Evaluation In Medium Voltage

Network 20 KV Feeder Bojo PT. PLN (Persero) Rayon Mattirosi. (2013)

Riski, Aldi. The Influence of Adding Networks to Drop Voltage at SUTM 20 kV Grade Feeder Tuo Rayon Kersik Tuo Kerinci District. (2013)

Ramdan M and Herawan F 2016 “Analisis Kehandalan Kinerja Penyulang 20 kV Di PT . PLN (Persero) Distribusi Jawa Barat Area Cirebon Rayon Ciledug” no. 1301475.

Shadri, “Analisa Perhitungan Susut Teknis dengan Pendekatan Kurva Beban pada Jaringan Distribusi PT PLN (Persero) Rayon Bireuen,” Tugas Akhir pada Jurusan Teknik Elektro Universitas Malikussaleh, Lhokseumawe, 2018.

Santoso R 2016 “Evaluasi Tingkat Keandalan Jaringan Distribusi 20 kV Pada Gardu Induk Bangkinang Dengan Menggunakan Metode FMEA (Failure Mode Effect Analysis)” Jurnal Online Mahasiswa Fakultas Teknik Universitas Riau 3 (2) pp. 1-7.

Wicaksono H P and Hernanda I G N S 2012 “Analisis Keandalan Sistem Distribusi Menggunakan Program Analisis Kelistrikan Transien dan Metode Section Technique” J. Tek. Its 1 (1) pp. 153–158.

Published

23-10-2024

How to Cite

Analysis Of Load Balance In 20 Kv Distribution Systems On Power Losses. (2024). Journal of International Multidisciplinary Research, 2(10), 97-106. https://doi.org/10.62504/jimr892

Similar Articles

1-10 of 12

You may also start an advanced similarity search for this article.